FM200 Gas System Without Pollution For Museum ≤10s Spraying Time

Brand Name : Air Giant

Model Number : QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2

Certification : CAL,CMA,CNAS,ILAC-MRA,CCC

Place of Origin : China

MOQ : 1 set

Price : negotiation

Payment Terms : L/C, D/P, T/T, Western Union, Paypal, Credit card

Supply Ability : 28000 sets per week

Delivery Time : 10-15 working days

Packaging Details : Plywood outer box with bubble bag or paper

Storage Pressure : 4.2MPa

Spraying Time : ≤10s

Filling Density : ≤950kg/m3

Nominal Pressure : 5.3MPa

Test Pressure : 8.4MPa

Working Power : DC 24V 1.6A

Working Temperature : 0℃~50℃

Protected Zone Range : Proportion: ≤800m² ; Volume: ≤3600m³

Starting Mode : Automatic, Electrical Manual, Mechanical Manual

Cylinder Volume : 40L、70L、100L、120L、150L、180L

Contact Now

FM200 Gas System Without Pollution For Museum

Description

• Automatic HFC-227ea/FM200 fire extinguishing system is a set of fire extinguishing, automatic control and fire detection in one system which is the modern intelligent automatic fire extinguishing device.

• HFC-227ea/FM200 is a kind of colourless, odorless, tasteless,noncorrosive, electrical insulated, non-conductive fire agent.

• The ozone-depleting potential value is zero.

• It is currently an ideal substitute for the halon extinguishing agent.

• Assemble agent according to different filling pressure, different capacity, different extinguishing agent and different starting mode.

Physical and chemical properties

Chemical Formula: The FM200 (Heptafluoropropane, HFC-227ea) Fire Suppression System uses a synthetic, organic compound called heptafluoropropane (HFP) as its active agent. The chemical formula for HFP is C3HF7.

1.Colorless and Odorless: FM200 (Heptafluoropropane, HFC-227ea) is a colorless, odorless gas that is difficult to detect without specialized equipment.

2.Non-Corrosive: FM200 (Heptafluoropropane, HFC-227ea) is non-corrosive, meaning it does not react with or damage metals, plastics, or other materials commonly found in buildings and equipment.

3.Low Toxicity: FM200 (Heptafluoropropane, HFC-227ea) has a low toxicity level, which means it is safe for human occupancy when used in accordance with design and installation guidelines.

4.High Boiling Point: FM200 (Heptafluoropropane, HFC-227ea) has a high boiling point of 16.4 °C (61.5 °F), which means it remains in a gaseous state at room temperature and pressure. This property allows it to quickly disperse and distribute throughout an enclosed space to suppress a fire.

5.Non-Conductive: FM200 (Heptafluoropropane, HFC-227ea) is non-conductive, which means it does not conduct electricity. This property makes it safe to use in areas where electrical equipment is present.

6.Low Global Warming Potential: FM200 (Heptafluoropropane, HFC-227ea) has a low global warming potential (GWP) of 0.02, which is much lower than other commonly used fire suppression agents such as halon.

7.Rapid Extinguishing Action: FM200 (Heptafluoropropane, HFC-227ea) can extinguish fires quickly by removing heat from the fire triangle, interrupting the chemical chain reaction, and reducing the concentration of oxygen in the protected space.

Components

The pipe network model of FM200 fire suppression system consists of actually three parts: the pipe network part, the fire fighting equipment part and the electrical elements part. Here will explain the last two parts for customers.

The electrical elements is a set of detecting device, and it always plays a subsidiary role in each system. The electrical elements includes:several control panels, several manual buttons, some discharge indicator lights, some alarm bells, some sounder with light, some smoke detectors and heat detectors.

The main part of the system is fire fighting equipment. It is formed by several components: FM200 cylinders, a cylinder frame, nitrogen-pressure driving devices, a driving device frame, container valves, flexible hoses, liquid flow check valves, gas control pipes, gas flow check valves, manifolds, safety valves, selective valves, flanges, elbows and nozzles.

FM200 Gas System Without Pollution For Museum ≤10s Spraying Time

FM200 Gas System Without Pollution For Museum ≤10s Spraying Time

Application

• Computer room, communication room, power distribution room, library, archives,

Museum, etc.

• Be used for electrical fire, liquid fire, solid fire, gas fire which can be cut off the gas

source before extinguishing occur, etc.

FM200 Gas System Without Pollution For Museum ≤10s Spraying Time

Advantages

The FM200 Fire Suppression System is a popular choice for protecting sensitive and valuable equipment and materials in a variety of settings. Here are some of its advantages:

  1. Quick and Effective Suppression: FM200 is a fast-acting agent that can quickly suppress fires without causing harm to people or the environment. It can extinguish fires in as little as 10 seconds, which can help prevent significant damage and downtime.
  2. Safe for Human Occupancy: FM200 is a clean agent, meaning that it does not leave any residue or damage to equipment, electronics, or sensitive materials. It is also safe for human occupancy since it has low toxicity levels and does not displace oxygen in confined spaces.
  3. Non-Conductive: FM200 is a non-conductive agent, which means that it can be used in areas where electrical equipment is present, such as data centers, server rooms, and other critical facilities. It can effectively suppress fires without damaging sensitive electronic equipment.

Packages

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

FM200 Gas System Without Pollution For Museum ≤10s Spraying Time


Product Tags:

FM200 Gas System Without Pollution

      

Museum FM200 Gas System

      
China FM200 Gas System Without Pollution For Museum ≤10s Spraying Time factory

FM200 Gas System Without Pollution For Museum ≤10s Spraying Time Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Air Giant Fire Equipment Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)